Halogen-Free Cable RZ1-K 3x1.5mm - 100m Roll
3-wire halogen-free electrical cable with a 1.5mm diameter. Supplied in 100-metre rolls.
Made of green thermoplastic material, flame-retardant, designed to withstand the demanding requirements of industrial installations.
Cable tube approved according to UNE EN 60228. Suitable for outdoor and indoor use. AENOR RZ1-K certification.
- Conductor: Class 5 flexible polished copper, according to UNE EN 60228
- Insulation: CROSS-LINKED POLYETHYLENE DIX-3 (XLPE), according to UNE 21123-4
- Conductor arrangement: Concentric layer wiring
- Sheath: Thermoplastic polyolefin, according to UNE EN 21123-4
Halogen-free Cable RZ1-K (AS) 3x1,5 mm² - 100 m roll
A safer installation with a halogen-free cable RZ1-K (AS) with a 3x1,5 mm² cross-section. Fire-resistant and non-flame-propagating, with low smoke and corrosive-gas emission, it is mandatory in new buildings and public-assembly premises. Sold in 100-metre rolls.
🔌 3x1,5 mm²⚡ 600/1000 V🌡 -15 à +90 ºC🔥 Halogen-free
| 3x1,5 mm² Cross-section | 600/1000 V Voltage | -15 à +90 ºC Temperature | 100 m Roll |
The halogen-free RZ1-K (AS) cable with a 3x1,5 mm² cross-section ensures a safe installation: its main strengths are its fire resistance and its excellent ability not to propagate flame. Its use is mandatory in new buildings and public-assembly premises, where low smoke and corrosive-gas emission is essential in the event of fire.
It is made of a flexible class-5 polished copper conductor to UNE EN 60228, with cross-linked polyethylene XLPE (UNE 21123-4) insulation. Its operating voltage is 600/1000 V (test voltage 3500 V) and its operating temperature range runs from -15 à +90 ºC. Suitable for indoor and outdoor use. It is sold in 100-metre rolls and is commonly installed in conduits, on surfaces or recessed.
Why choose this product?
Non-flame-propagating, with low smoke and corrosive-gas emission.
Class-5 copper conductor to UNE EN 60228.
Required in new buildings and public-assembly premises.
Technical specifications
| Product type | Halogen-free electrical cable |
|---|---|
| Designation | RZ1-K (AS) |
| Cross-section | 3x1,5 mm² |
| Conductor | Flexible class-5 polished copper (UNE EN 60228) |
| Insulation | Cross-linked polyethylene xlpe (une 21123-4) |
| Operating voltage | 600/1000 V |
| Test voltage | 3500 V |
| Operating temperature | -15 à +90 ºC |
| Approx. outer Ø | 9,1 mm |
| Weight | 115,5 kg/km |
| Resistance at 20ºC | 13,3 Ω/km |
| Packaging | 100 m roll |
Advantages
- Halogen-free: low smoke and corrosive-gas emission in case of fire.
- Non-flame-propagating: limits the spread of fire.
- Class-5 copper conductor: high flexibility to UNE EN 60228.
- Standards-compliant: suitable for fixed indoor installations.
- 100 m roll: convenient packaging for your installations.
Recommended applications
| 🚪 | Hospitals and health centres — enhanced fire safety. |
| 🏠 | Cinemas and theatres — public-assembly premises. |
| 🏛 | Schools and public buildings — mandatory halogen-free installations. |
| 🌿 | Surface or recessed conduits — fixed indoor installations. |
Installation guide
| 1 | Switch off the power Cut the supply before any work. |
| 2 | Prepare the run Lay the cable in the conduit, on the surface or recessed, as required. |
| 3 | Make the connection Connect the conductor in line with applicable electrical regulations. |
| 4 | Check the installation Verify insulation and proper tightening before energising. |
Frequently asked questions
That the cable emits little smoke and corrosive gas in case of fire and does not propagate flame.
Its operating voltage is 600/1000 V, with a test voltage of 3500 V.
In 100-metre rolls.
| 🔥 Halogen-free Fire safety | ✅ UNE EN 60228 Compliant | 🔌 3x1,5 mm² Class-5 copper | 📦 100 m roll In stock |
Data sheet
- Power source (V)
- 600/1000V
- Measures (mm)
- 100m.
- Material
- Polietileno + Polilefina + Cobre
- Operating temperature
- -15ºC ~ +90ºC
- Certification
- CE - RoHS
UNE EN 60228+UNE 21123-4
- Warranty
- 2 años